Buzzing, clicking, grinding, hissing: what each AC noise usually means

Buzzing at the outdoor unit is electrical, usually a capacitor or contactor. Rapid clicking is a relay or thermostat problem. Grinding or squealing is a motor bearing. Hissing is a refrigerant or duct leak. A bang on startup is the compressor or a loose blower. Gurgling is a drain or a low charge. Turn the system off for grinding, banging and loud hissing; the rest can wait for a scheduled visit.

Buzzing

Steady buzzing from the outdoor unit with the fan still is the classic failed capacitor. Buzzing that comes and goes with the unit cycling is more often the contactor, the switch that sends power to the compressor. Buzzing when the thermostat is not calling means the contactor is stuck closed, which runs the compressor nonstop and needs attention the same day. A faint buzz from the indoor unit's transformer is normal.

Clicking

One click when the system starts and one when it stops is the contactor doing its job. Rapid or repeated clicking without the system starting is a relay, a control board or a thermostat with weak batteries trying and failing to call. Change the thermostat batteries first; it is the cheapest fix on this page.

Grinding and squealing

Bearings. Either the condenser fan motor outside or the blower motor inside. A squeal that rises and falls with speed is the same thing earlier in its life. Turn the system off: a motor that seizes can take the capacitor and, in the case of the blower, overheat the furnace. Motor replacement is a few hundred dollars; letting it seize on a 105-degree day adds the wait.

Hissing

At the outdoor unit or along the copper lines, hissing is refrigerant escaping and the system should be turned off until a technician finds the leak. At a supply register or in the attic, hissing is more often a duct leak, which wastes money rather than equipment. A steady loud hiss or a bubbling sound at the indoor coil is a larger leak and the system should not run.

Banging and rattling

A bang when the compressor starts can be a compressor with internal damage or a hard-start problem, and a rattle from the outdoor unit is usually a loose panel or debris in the fan. Loose panels are a homeowner fix; anything from inside the compressor is a professional diagnosis and often a repair-or-replace conversation.

Gurgling and dripping

Gurgling at the indoor unit is water in a partly blocked drain line or, less often, refrigerant moving through a low charge. Dripping over a window or eave is the attic overflow pan's secondary drain telling you the primary line is clogged. Both are in our drain line guide.

Questions on this

My outdoor unit got loud this summer but works fine. Is that a problem?

A unit that is louder than it was is usually a fan motor bearing starting to go or a fan blade out of balance from a bent blade or debris. It will work until it does not, and that day is a hot one. A tune-up catches it for the price of the visit.

The ducts pop when the system starts. Normal?

Popping or ticking from the ducts is sheet metal expanding as it warms or cools and is normal in attic systems. A loud bang from the duct every start can mean a return that is undersized and pulling the metal in, which a technician can measure.